icras
icras benefitsicras solutionsicras applications

Technical data

Power class

002F

003F

004F

005F

007F

011F

015F

018F

022F

030F

037F

045F

055F

075F

090F

110F

132F

Power (kVA) at 400V

4.5

5.5

7

9

13

17

22

29

33

40

50

60

75

100

120

150

170

Output current In (A)

6.5

8

10

13

18

24

32

42

48

60

75

90

110

150

180

210

245

Max. current 1min (A)

10

12

15

20

27

36

48

63

72

90

113

135

165

225

270

315

368

Overloadability 1.5 x In, 1min/10min
Max. output voltage Equal to supply voltage
Supply
Supply voltage 380-500VAC
Allowable voltage fluctuation +/- 10%
Nominal supply frequency 50/60Hz +/- 5%
Signal input levels
Digital controls S1, S2, DIA3, DIA4, DIA5, DID1, DID2, DID3, DID4, DID5: 42 … 240VAC; 15mA
Analog references AIN1: 0 … +10V and AIN2: -10 … +10V; 200kΩ; accuracy 0.5%
Encoder feedback EA+/- and EB+/-; 0/24V; 3kΩ; floating differential inputs
Control features
Control method Open loop or closed loop vector control
Frequency control range 0 ... 250Hz
Frequency command Potentiometer, motor potentiometer, 2-4-step controller or 0 ... 10V analog signal
Limit switch functions Slowdown and stop limit inputs for both directions
Speed control range Open loop vector control
    sN ... 100% (sN= motor nominal slip)
Closed loop vector control
    0 ... 100%
Speed accuracy Open loop vector control
    1% of nominal speed at speed range 10 ... 100%
    1/3 of motor nominal slip at speed below 10%
Closed loop vector control
    0.01% of nominal speed
Extended speed range 100 ... 200%
Braking torque 150%
Protections
Stall prevention During acceleration and constant speed
Motor overload protection Thermistor based temperature measurement
Overload protection Fault is detected if the current momentarily exceeds 280% of rated current
Undervoltage / blown fuse Fault is detected if DC voltage drops below 333V
Overvoltage protection Fault is detected if DC voltage exceeds 911V
Momentary power loss Immediate fault stop
Inverter overtemperature Temperature sensor on the heat sink
Mechanical brake Circuit breaker
Braking transistor Electronic supervision for the braking chopper and for the braking resistor
Ground fault Provided by electronic circuitry
Overspeed / stall,  
speed difference supervision Independent measurement using pulse wheel or encoder
Ambient conditions
Ambient temperature -10°C ... +55°C (14°F ... 131°F) for ED≤60%
Storage temperature -40°C ... +60°C (-31°F ... 140°F) dry. Power on >1h in a year.
Humidity <95%RH (no condensation)
Altitude Maximum 1000m at In. Above 1000m: In reduces 1% per each 100m.
Above 3000m: consult factory.
Vibration Operation: maximum displacement amplitude 3mm at 2-9Hz.
Maximum acceleration amplitude 0.5g (5m/s_) at 9-200Hz
Conforms to LV and EMC directives.
up

innocrane
home
company
partners
links
faq
contact

INNOCRANE
Kankurinkatu 4-6
05800 Hyvinkää
FINLAND

phone +358 19 8712 200
mobile +358 400 687 652
fax +358 19 8712 205